Hot

Agilent 8890 5977A GCMS FID System with 7693 Autosampler & Computer

Fully Tested and Refurbished

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Agilent 8890 5977A GCMS FID System with 7693 Autosampler has been fully tested and refurbished at our in-house testing laboratory.

The Agilent 8890 GC with 5977A Mass Selective Detector (GC/MS), FID, 7693 Autosampler, and computer is a versatile analytical platform designed for comprehensive analysis of volatile and semi-volatile compounds in complex matrices. The Agilent 8890 GC provides precise temperature control, advanced electronic pneumatic control (EPC), and excellent chromatographic reproducibility, while the 5977A MSD enables reliable compound identification and quantification through mass spectrometry. The addition of a Flame Ionization Detector (FID) allows simultaneous or complementary detection of hydrocarbons and organic compounds with a wide linear range, supporting both qualitative and quantitative workflows. The integrated 7693 Autosampler ensures precise, repeatable automated injections and high-throughput batch processing. This configuration is widely used in environmental testing, petrochemical analysis, food safety, and pharmaceutical laboratories, supporting workflows aligned with EPA, ASTM, USP, and AOAC methods where both GC-MS and GC-FID capabilities are beneficial.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 8890 5977A GCMS FID System with 7693 Autosampler & Computer has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 8890 5977A Inert GCMS System with 7693 Autosampler & Computer

  • Agilent 5977A Inert MSD EI Turbo Pump
  • Agilent 8890 GC Gas Chromatograph
  • Flame Ionization Detector | FID
  • Agilent 7693 Autosampler Tray with 150 Vial Tray with three removable (50-Vial) Racks
  • Agilent 7693 Autosampler Injector Tower
  • Foreline Pump
  • Computer Workstation with Software
  • All Required Power and Communication Cables
  • Extended Warranty Available & Quoted Upon Request

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

Agilent 8890 5977A GCMS FID System with 7693 Autosampler: Applications in Pharma, Food, and Environmental Labs

The Agilent 8890 GC System with Agilent 5977A GC/MSD, Flame Ionization Detector (FID), and Agilent 7693 Autosampler is widely used for advanced gas chromatography and mass spectrometry analysis in environmental, pharmaceutical, food safety, petrochemical, forensic, chemical, and industrial laboratories. Common laboratory applications include volatile organic compound (VOC) and semi-volatile organic compound (SVOC) analysis following EPA Methods 524, 8260, and 8270, residual solvent testing aligned with USP <467>, hydrocarbon characterization, flavor and fragrance profiling, pesticide screening, and forensic toxicology workflows. Environmental laboratories commonly utilize the system for air, water, and soil contaminant analysis, while petrochemical laboratories rely on it for fuel composition testing, refinery gas analysis, and hydrocarbon quantitation. The dual-detector GCMS/FID configuration enables simultaneous mass spectrometric identification and quantitative FID analysis from a single injection, improving analytical flexibility and laboratory efficiency. The Agilent 5977A GC/MSD delivers sensitive compound identification and spectral confirmation, while the FID provides robust quantitation of hydrocarbons and organic compounds with a wide linear dynamic range. Combined with automated sample handling from the 7693 Autosampler, stable chromatographic performance, low carryover, and dependable reproducibility, the Agilent 8890 5977A GCMS FID System supports routine and high-throughput analytical workflows across regulated and research-based laboratory environments.


Agilent 8890 5977A GCMS FID System with 7693 Autosampler: Refurbished System Benefits and Pricing

New systems typically range from approximately $165,000 to $185,000, depending on inlet configuration, detector options, software packages, and automation features, while certified refurbished systems generally range from $60,000 to $78,000, offering substantial savings on initial capital investment. In addition to acquisition costs, laboratories should consider ongoing operational expenses such as carrier gases, GC columns, septa, liners, syringes, vacuum pump maintenance, ion source cleaning, detector consumables, autosampler maintenance, calibration standards, preventive maintenance, software licensing, and compliance-related qualification support for EPA, USP, FDA, ISO, AOAC, and cGMP workflows. Long-term ownership considerations may also include turbomolecular pump servicing, replacement electronic components, FID maintenance, and optional service contracts to maintain stable chromatographic performance and dependable mass spectrometry sensitivity in high-throughput laboratory environments. Purchasing a certified refurbished Agilent 8890 5977A GCMS FID System with 7693 Autosampler allows laboratories to significantly reduce ownership costs while still benefiting from simultaneous GC-MS and FID analysis, automated sample handling, reliable compound identification, and proven long-term analytical performance for regulated and research-based laboratory applications.


EPA Method 8270E: Semivolatile Organic Compounds by GCMS Using Agilent 8890 5977A GCMS FID System with 7693 Autosampler

The Agilent 8890 GC System with Agilent 5977A GC/MSD, Flame Ionization Detector (FID), and Agilent 7693 Autosampler provides a highly capable and reliable analytical platform for laboratories performing EPA Method 8270E for the determination of semivolatile organic compounds (SVOCs) in environmental samples. This configuration delivers excellent chromatographic resolution, sensitive mass spectrometric detection, and dependable quantitative reproducibility for complex SVOC analysis in water, soil, sediment, sludge, and waste matrices. The Agilent 5977A GC/MSD provides accurate compound identification and spectral confirmation for priority pollutants such as phenols, polycyclic aromatic hydrocarbons (PAHs), phthalates, nitroaromatics, and chlorinated organic compounds, while the integrated FID offers additional hydrocarbon quantitation capability and analytical flexibility for petroleum-related applications. The Agilent 8890 GC platform delivers precise oven temperature control, stable carrier gas flow, low carryover, and reliable retention time performance critical for EPA Method 8270E workflows, while the 7693 Autosampler enhances throughput through automated and reproducible sample introduction. Combined with strong sensitivity, dependable system stability, and compatibility with high-throughput environmental testing workflows, the Agilent 8890 5977A GCMS FID System with 7693 Autosampler provides laboratories with excellent analytical confidence and operational efficiency for EPA Method 8270E SVOC analysis applications.